Technical Specification

Plate Counting Manual entry of count data via Plate Editor utility. Counts can be captured directly from automatic colony counting systems such as Sorcerer.
Study Scope No constraints for numbers of Studies, Experiment Folders, Experiments, Test substances, Strains, Control sets, Positive control chemicals etc.
Study Details Name, Start Date, Study Type, Test Substance, Description, Client, Study Director. Any number of additional fields configurable. Can be configured as compulsory or optional entries.
Experiment Scope Each subset of plates within an experiment may be configured differently for dose levels, strains, number of plates, metabolic activation etc.
Experiment Folders Allows grouping of Experiments and Controls that share common incubation time, method etc.
Experiment Details Name, Start Date, Type, Description, Solvent, Justification for solvent used, Solubility. Any number of additional fields configurable. Can be configured as compulsory or optional entries.
Test Substances Name, CAS No., Reference No., Batch, Origin, Physical Nature, Properties, Stability, Storage Conditions.
Plate Groups Test substance, Solvent control, Untreated control, Viability, Positive control (1 or 2 sets).
Plate Postfixes Unlimited number of plate postfix codes for observations such as Incomplete lawn, Precipitation etc. Can be applied to single or multiple plates.
Positive Controls Control code, Date created, CAS No., Reference No, Manufacturer, Manufacturer part No., Batch, Description. 1 or 2 sets of positive controls for each strain.
Negative Controls Type (solvent, untreated), Description, Solvent. Ability to add viability plates by strain.
Strains Name, Description, Default positive control associations for -S9 & +S9 mixes. Each strain is independently configurable within an experiment or control.
Dose Levels Unlimited number of dose levels. Different dose levels can be assigned to -S9 & +S9 mixes in the same experiment.
Templates New Studies, Experiments & Control Sets can be based upon configurable templates.
Experiment Reports Experiment preparation, data and plate audit reports in Microsoft Word format. Custom reports produced if required.
Experiment Folder Security Within an Experiment Folder, plates can be locked against accidental or unauthorized changes.
User Levels User, Advanced User, Study Director, System Administrator, Auditor.
User Access Rights System Administrator can assign 47 different rights for each user level. Menus and options can be enabled, read-only or disabled.
Minimum Specification IBM PC compatible Pentium II 350Mhz processor with 128MB RAM, Windows NT 4.0, 2000 or XP with Oracle 8i or higher & Microsoft Word 2000 for report generation.